Title: power window trip switch
Post by zaketh on Sep 17th, 2006, 4:04pm
Hi,does anybody know where the trip switch for power window?have N reg ultima and today the front windows wont go back up have looked in owners manuel and it says in fuse layout that the switch i need is an auxilary fuse outside main fuse boxes and is located in drivers door,have had this apart and i can't see a brown relay antwhere,i hope someone can help else i'll be sleeping in the car tonight,Regards Damon

Title: Re: power window trip switch
Post by stafford on Sep 17th, 2006, 4:20pm
have you looked on the faults page on the front of thi site... good luck

Title: Re: power window trip switch
Post by solarpanel on Sep 17th, 2006, 4:26pm
just looked in the door and i cant see it try disconnecting battery wait 30mins then reconnect see if that does it HTH

Title: Re: power window trip switch
Post by Simmo on Sep 17th, 2006, 5:13pm
Zaketh. It has been said previously that the 'brown' relay in the door doesn't exist!!!. Beyond that I can't help but there seem to be many 'oddities' like this with the Scorpio especially as far as electrics are concerned.

Title: Re: power window trip switch
Post by harry.m1byt on Oct 22nd, 2006, 11:24pm
If they are similar to the Granada and many of the parts used are the same, then the trip is in the motor itself. It's a themal trip which should reset itself once the motor cools down.  

Title: Re: power window trip switch
Post by TiberiuS on Oct 23rd, 2006, 12:23pm

on 10/22/06 at 23:24:45, harry.m1byt wrote:
If they are similar to the Granada and many of the parts used are the same, then the trip is in the motor itself. It's a themal trip which should reset itself once the motor cools down.  


Sometimes though they open with the heat and never close again, you have a deceased motor unless you want to start delving into the field windings ;). Unusual though in these sort of motors, wouldn't be working long enough to get hot in normal use, thermal cut-outs are there to stop the thing melting in extreme cases.

Dead windings in 2 motors at a time is unlikely though...You haven't overrun the circuit by running 2 windows at the same time?


If it still won't work then you could start checking for voltage and bad looms/earths...

Regards, Bruce.